operating ambient temperature

  • 1 operating ambient temperature

    operating ambient temperature Betriebsumgebungstemperatur f

    English-German dictionary of Electrical Engineering and Electronics > operating ambient temperature

  • 2 operating ambient temperature

    <tech.gen> ■ Betriebsumgebungstemperatur f

    English-german technical dictionary > operating ambient temperature

  • 3 ambient temperature

    <tech.gen> (temperature range of operating environment; e.g. -40 to +60 °C) ■ Umgebungstemperatur f
    < hvac> (inside a building etc.; typ. 68 deg F) ■ Raumtemperatur f (RT); Umgebungstemperatur f ; Zimmertemperatur f ugs ; Innentemperatur f ugs ; normale Temperatur f ugs.rar

    English-german technical dictionary > ambient temperature

  • 4 ambient operating temperature

    ambient operating temperature Betriebsumgebungstemperatur f

    English-German dictionary of Electrical Engineering and Electronics > ambient operating temperature

  • 5 ambient

    pract <tech.gen> (temperature range of operating environment; e.g. -40 to +60 °C) ■ Umgebungstemperatur f
    <tech.gen> ■ Umgebungs...

    English-german technical dictionary > ambient

  • 6 длительный допустимый ток

    1. Strombelastbarkeit, f
    2. Dauerstrombelastbarkeit, f

     

    (длительный) допустимый ток
    Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
    [ ГОСТ Р МЭК 60050-826-2009]

    Этот ток обозначают IZ
    [ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]

    EN

    (continuous) current-carrying capacity
    ampacity (US)
    maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
    [IEV number 826-11-13]

    ampacity
    The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
    [National Electrical Cod]

    FR

    courant (permanent) admissible, m
    valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
    [IEV number 826-11-13]

    Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:

    • its insulation temperature rating;
    • conductor electrical properties for current;
    • frequency, in the case of alternating currents;
    • ability to dissipate heat, which depends on cable geometry and its surroundings;
    • ambient temperature.

    Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.

    The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.

    In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.

    Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.

    The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.

    For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.

    Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.

    When designing an electrical system, one will normally need to know the current rating for the following:

    Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.

    [http://en.wikipedia.org/wiki/Ampacity]

    Тематики

    • электротехника, основные понятия

    Синонимы

    EN

    DE

    • Dauerstrombelastbarkeit, f
    • Strombelastbarkeit, f

    FR

    • courant admissible, m
    • courant permanent admissible, m

    Русско-немецкий словарь нормативно-технической терминологии > длительный допустимый ток

См. также в других словарях:

  • Operating temperature — An operating temperature is the temperature at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the device function and application context, and… …   Wikipedia

  • Distributed temperature sensing — systems (DTS) are optoelectronic devices which measure temperatures by means of optical fibres functioning as linear sensors. Temperatures are recorded along the optical sensor cable, thus not at points, but as a continuous profile. A high… …   Wikipedia

  • Thermodynamic temperature — is the absolute measure of temperature and is one of the principal parameters of thermodynamics. Thermodynamic temperature is an “absolute” scale because it is the measure of the fundamental property underlying temperature: its null or zero point …   Wikipedia

  • Normal human body temperature — 98.6 redirects here. For other uses, see 98.6 (disambiguation). Normal human body temperature, also known as normothermia or euthermia, is a concept that depends upon the place in the body at which the measurement is made, and the time of day and …   Wikipedia

  • Trace heating — Electric Trace Heating, also known as Electric Heat Tracing and Electric Surface Heating, is a system used to maintain or raise the temperature of pipes and vessels. Trace heating takes the form of a electrical like heating element run in… …   Wikipedia

  • Dhama Innovations Pvt. Ltd. — Dhama Innovations Pvt. Ltd. Type private Indus …   Wikipedia

  • WDC 65C265 — The Western Design Center (WDC) W65C265S microcomputer is a complete fully static 16 bit computer fabricated on a single chip using a Hi Rel low power CMOS process. The W65C265S complements an established and growing line of 65xx products and has …   Wikipedia

  • рабочая окружающая температура — — [Я.Н.Лугинский, М.С.Фези Жилинская, Ю.С.Кабиров. Англо русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.] Тематики электротехника, основные понятия EN operating ambient temperatureOAT …   Справочник технического переводчика

  • Crystal oscillator — A miniature 4 MHz quartz crystal enclosed in a hermetically sealed HC 49/US package, used as the resonator in a crystal oscillator. A crystal oscillator is an electronic oscillator circuit that uses the mechanical resonance of a vibrating crystal …   Wikipedia

  • Jet engine performance — This article describes how jet engine performance is estimated during the design phase. Similar techniques are used once the engine has been built and is being tested, except the performance of individual components, rather than being assumed, is …   Wikipedia

  • Computer cooling — An OEM AMD heatsink mounted onto a motherboard. Computer cooling is required to remove the waste heat produced by computer components, to keep components within their safe operating temperature limits. Various cooling methods help to improve… …   Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»